Related Experiment Video
Updated: May 21, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Patient Harm Associated with Flexible Ureteroscopes: A Cross-Sectional Analysis of FDA MAUDE Reports with
Dilmurat Akhmetov1, Sayat S Oraz2, Dastan T Kambarov2
1Department of Urology and Kidney Transplantation, National Scientific Center of Surgery, Almaty, Kazakhstan.
Background:
Adverse events associated with flexible ureteroscopes are increasingly reported to postmarket surveillance systems; however, the lack of standardized harm classification limits reproducibility and actionable insights.
Objectives:
To develop and reliability-test a reproducible taxonomy for classifying patient harm and death in Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) reports (2020-2025) and to characterize mechanisms and severity profiles.
Methods:
We conducted a retrospective cross-sectional analysis of 532 MAUDE reports (product class: ureteroscopes; event: injury/death). Following the exclusion of nontarget devices (n = 212), literature-only records (n = 129), no-harm reports (n = 5), and duplicates (n = 39), 148 unique reports (including 1 death) were analyzed. Two independent clinicians coded reports using a prespecified taxonomy for (1) primary harm category, (2) harm mechanism, and (3) severity grade. Inter-rater reliability was quantified using unweighted and weighted Cohen's kappa (κ).
Results:
Inter-rater reliability was substantial for the primary harm category (κ = 0.82; 95% confidence interval [CI] 0.76-0.88; 86% agreement) and severity grade (weighted κ = 0.79; 95% CI 0.71-0.87) but moderate for mechanism (κ = 0.61). Traumatic (31.1%) and infectious (30.4%) categories predominated. Operational harm (clinical consequences without tissue injury) accounted for 20.3%. Most events (69.4%) were moderate or severe. While breakage/detachment was the most common mechanism (27.0%), 48.0% of reports lacked sufficient detail for classification. Reports involving reprocessing/contamination were disproportionately severe (63.6%). The single death involved septic shock with findings suggestive of device bioburden.
Conclusions:
This reliability-tested taxonomy enables reproducible harm phenotyping in passive surveillance. However, nearly half of MAUDE narratives lack sufficient detail for mechanism coding. As a passive system lacking exposure denominators, MAUDE supports analysis of reporting composition but not incidence estimation or valid between-device comparisons.
Related Concept Videos
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Urinary Tract Calculi V: Nursing Management
Drug Regulation
Urinary Tract Calculi III: Medical Management
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urinary Tract Calculi VI: Surgical Management