Related Experiment Video
Updated: May 22, 2026

Use of 3D Robotic Ultrasound for In Vivo Analysis of Mouse Kidneys
Published on: August 12, 2021
Attention-Based Point Cloud Completion for CT-Equivalent Kidney Volumetry from Tracked Freehand Ultrasound
Sikai Ge1,2, Wuwei Ma3, Hao Tang1
1Department of Urology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210002, China.
Abstract:
Kidney volume measurement is critical for managing polycystic kidney disease and monitoring transplants, but computed tomography involves radiation and conventional ultrasound has 20-30% error. This study validates tracked freehand ultrasound with attention-based point cloud completion for kidney volumetry, with the primary objective of determining equivalence to computed tomography within a ± 2% margin. Sixty healthy volunteers (30 male, 30 female; mean age 44 years; enrolled March-August 2024; 120 kidneys) undergoing routine health examination computed tomography underwent electromagnetic-tracked ultrasound using three standardized scanning maneuvers and same-day computed tomography. Sparse point clouds from ultrasound were completed using an attention-based transformer network (PointAttN) and four benchmark architectures. Volumes were compared against computed tomography using equivalence testing on per-kidney relative differences within a ± 2% margin. Tracked freehand ultrasound achieved mean absolute error of 3.94 mL (3.0% relative error) in multiaxis merged mode and passed statistical equivalence testing (TOST: p1 < 0.001, p2 = 0.043). Single-axis scanning failed equivalence testing across all methods with 2-4 times higher errors. Tracked freehand ultrasound with attention-based point cloud completion demonstrates kidney volume measurement accuracy approaching CT-level precision in healthy volunteers, passing formal statistical equivalence testing within a 2% margin. These algorithm-based results require validation in clinical populations with renal pathology and comparison with radiologist assessment before broader deployment. Multiaxis scanning is necessary for clinical accuracy.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: Kidney, Ureter, and Bladder Studies

