Oxygenator failures during cardiopulmonary bypass lead to associated injury patterns
Jace C Bradshaw1,2, AlleaBelle Bradshaw3, Rishab Agarwal3
1Departments of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Abstract:
BackgroundCardiopulmonary bypass (CPB) oxygenators provide essential intra-operative gas exchange. Although rare, CPB oxygenator failures can cause catastrophic morbidity and mortality, and published analyses of CPB-specific oxygenator failures are limited. We aimed to study reports of CPB oxygenator failures to observe patterns to inform preparation and device improvement.MethodsWe retrospectively reviewed Manufacturer and User Facility Device Experience (MAUDE) reports (April 2015-April 2025) of CPB oxygenator failures resulting in injury or death. ECMO events, malfunctions without harm, and duplicates were excluded. Manufacturer, device problem, and patient problem were compared between injury and death cohorts using chi-square or Fisher's exact tests. Narrative reports underwent supervised natural language processing (NLP) to identify clinical themes.ResultsA total of 388 events met criteria: 279 injuries (71.9%) and 109 deaths (28.1%). Events were commonly related to six manufacturers. Manufacturer B and Manufacturer D devices were disproportionately represented in deaths (43.1% vs 11.1% of injuries, p < 0.001 and 12.84% vs 5.38% of injuries, p = 0.017), while Manufacturer A was more frequently linked to injuries (60.6% vs 22.9%, p < 0.001), although the incidence of failure for each manufacturer could not be calculated. The remaining manufacturers were evenly distributed among report types. Device problem categories differed by outcome: "Unexpected Device Operation" was significantly more common in deaths (7.3% vs 1.4%, p = 0.0054), whereas "Human Factors" were more common in injuries (11.8% vs 4.6%, p = 0.036). NLP identified intra-operative performance/monitoring failures, hemolysis and thromboembolic events, and post-procedural evaluation/quality management as common descriptions of device failure situations.ConclusionUsing MAUDE reports, CPB oxygenator failures causing harm show distinct manufacturer, device problem, and outcome patterns but incidence could not be determined. Reports of unexpected operational failures and thromboembolic complications are more often fatal. NLP enhances detection of clinically relevant patterns, supporting targeted safety strategies and device improvements.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue, improving...
Oxygen Transport in the Blood
Atelectasis II: Pathophysiology
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...