Background:
Since the first transcatheter aortic valve replacement (TAVR), there has been an exponential increase in the number of patients diagnosed and treated for aortic stenosis.
Case Summary:
A 79-year-old man, with severe symptomatic aortic stenosis and a past medical history of coronary artery bypass in 2006 and percutaneous coronary stent implantation in 2016, presented to our Heart Valve Center for pre-TAVR assessment. Preprocedural computed tomography angiography was completed on a positron emission tomography (PET)/computed tomography (CT) machine. The patient underwent successful implantation of TAVR, with no evidence of leak on postoperative echocardiographic assessment on days 1 and 30.
Discussion:
Cardiac computed tomography angiography is the established gold standard for pre-TAVR evaluation in patients with no absolute contraindications; we may soon face a resource saturation problem. Therefore, we should aim to use our resources wisely.
Novelty:
A possible solution to the issue of CT scanner saturation lies in using our resources more efficiently: for example, pre-TAVR planning could be performed on PET/CT scanners, providing comparable results.
Take-Home Message:
Pre-TAVR assessment can be safely performed on a PET/CT machine.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography