Related Experiment Video
Updated: May 24, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Hybrid BOTDA-DIC sensing for flexural behavior characterization of eco-concrete reinforced beams under four-point
Nuraziz Handika1, Daral Suraedi2, Jessica Sjah2
1Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Indonesia, Depok, 16424, Indonesia. n.handika@ui.ac.id.
Abstract:
This study investigates the performance of Brillouin Optical Time Domain Analysis (BOTDA) and Digital Image Correlation (DIC) for monitoring the flexural behavior of two reinforced concrete (RC) beams constructed using eco-concrete containing Palm Oil Boiler Ash (POBA) and nano-silica as partial cement replacement. Two simply supported beams (300 cm × 15 cm × 25 cm) with different concrete compressive strengths were tested under four-point bending until failure to evaluate the sensing performance under varying structural responses. Distributed strain from BOTDA and full-field displacement from DIC were compared with mid-span deflection measured by Linear Variable Differential Transformers (LVDTs). Both sensing systems successfully captured strain development and stiffness degradation. BOTDA recorded the progressive increase of tensile strain at the bottom fiber, reaching 10,000-18,000 µε, as cracking advanced, while DIC identified multiple flexural cracks with openings ranging from 0.05 to 3.28 mm. BOTDA-derived deflection showed good agreement with LVDT and DIC, with differences less than 7%. The findings highlight the complementary advantages of both systems: BOTDA provides distributed and continuous strain monitoring for global behavior, while DIC captures localized deformation and crack development with high precision. Together, these techniques offer a complementary and reliable approach for detailed structural assessment of reinforced concrete beams.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Non-destructive Tests for Concrete Strength
Fiber Reinforced Concrete