Related Experiment Video
Updated: May 25, 2026

Non-Invasive PET/MR Imaging in an Orthotopic Mouse Model of Hepatocellular Carcinoma
Published on: August 31, 2022
18F-FAPI-42 PET/MR for the Evaluation of Small (≤3 cm) Hepatic Lesions: A Preliminary Study
Yanyu Yang1, Dan Wang1, Bo Zhou2
1Department of Nuclear Medicine, Daping Hospital, Army Medical University, Chongqing, China (Y.Y., D.W., R.X., Y.L., J.S., X.L., X.C.).
Rationale And Objectives:
To evaluate the diagnostic performance of 18F-fibroblast activation protein inhibitor (FAPI)-42 PET/MR for small (≤3 cm) hepatic lesions and to compare it with MRI and 18F-fluorodeoxyglucose (FDG) PET/MR.
Materials And Methods:
This prospective study enrolled patients with suspected hepatic malignancies who underwent both 18F-FDG and 18F-FAPI-42 PET/MR. The maximum standardized uptake value (SUVmax) and tumor-to-background ratio (TBR) were recorded. Using histopathology or radiologic follow-up as reference standard, diagnostic performance was compared across imaging sets stratified by lesion size.
Results:
Twenty-five patients (17 males; median age 57.2 years) with 96 lesions were enrolled. SUVmax was comparable between 18F-FAPI-42 and 18F-FDG (5.08 ± 0.50 vs. 5.58 ± 0.39, P > 0.05), whereas TBR was significantly higher for 18F-FAPI-42 (6.90 ± 0.49 vs. 2.43 ± 0.16, P < 0.001). Lesion-based analysis showed that 18F-FAPI-42 PET exhibited higher sensitivity (97.6% vs. 72.9%, P = 0.023) and accuracy (96.9% vs. 75.0%, P = 0.021) than 18F-FDG PET, particularly for lesions ≤1 cm (96.6% vs. 66.1%, P = 0.038; 96.8% vs. 68.3%, P = 0.042). MRI showed lower diagnostic performance, while 18F-FAPI-42 PET, 18F-FDG PET/MR and 18F-FAPI-42 PET/MR all demonstrated superior sensitivity and accuracy, especially for lesions ≤1 cm (P < 0.05, all). In addition, 18F-FAPI-42 PET/MR altered clinical management in 20.0% of patients.
Conclusions:
18F-FAPI-42 PET/MR improved diagnostic sensitivity and accuracy for small hepatic lesions with predominant metastatic involvement, particularly those ≤1 cm. 18F-FAPI-42 PET/MR may represent a promising one-stop solution for small hepatic lesions.
Insights
18F-fibroblast activation protein inhibitor (FAPI)-42 PET/MR significantly enhances diagnostic accuracy for small liver lesions, especially those ≤1 cm. This imaging modality shows promise as a comprehensive solution for evaluating small hepatic lesions.
Area of Science:
- Radiology
- Oncology
- Nuclear Medicine
Background:
- Small hepatic lesions pose diagnostic challenges.
- Accurate characterization is crucial for timely management of potential malignancies.
Purpose of the Study:
- To assess the diagnostic performance of 18F-fibroblast activation protein inhibitor (FAPI)-42 PET/MR for small hepatic lesions (≤3 cm).
- To compare 18F-FAPI-42 PET/MR with MRI and 18F-fluorodeoxyglucose (FDG) PET/MR.
Main Methods:
- Prospective study of patients with suspected hepatic malignancies.
- Comparison of 18F-FAPI-42 PET/MR, 18F-FDG PET/MR, and MRI.
- Analysis of lesion size, SUVmax, and tumor-to-background ratio (TBR) against histopathology or follow-up.
Main Results:
- 18F-FAPI-42 PET/MR demonstrated significantly higher TBR compared to 18F-FDG PET/MR (P < 0.001).
- 18F-FAPI-42 PET/MR showed superior sensitivity (97.6%) and accuracy (96.9%) over 18F-FDG PET (72.9% and 75.0%, respectively).
- Performance was particularly enhanced for lesions ≤1 cm, with improved sensitivity and accuracy for 18F-FAPI-42 PET/MR (P < 0.05).
- Clinical management was altered in 20.0% of patients following 18F-FAPI-42 PET/MR imaging.
Conclusions:
- 18F-FAPI-42 PET/MR significantly improves diagnostic sensitivity and accuracy for small hepatic lesions, including those ≤1 cm.
- This modality offers a promising one-stop solution for the evaluation of small hepatic lesions.
- 18F-FAPI-42 PET/MR aids in altering clinical management for a notable percentage of patients.