Related Experiment Video
Updated: May 26, 2026

Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Comparison of three contrast agents in the diagnosis of cracked teeth using Cone Beam Computed Tomography (CBCT)
Mawadah K Alnaseri1, Ruaa A Alamoudi1, Hanadi Sabban2
1Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
Abstract:
Cracked teeth are difficult to detect on conventional cone beam computed tomography (CBCT). Contrast agents may improve visualization of fine and superficial cracks. This study compared three contrast agents for their diagnostic performance. Thirty-nine extracted premolars with induced micro-cracks were examined using three contrast agents: ioversol, barium sulfate, and meglumine ioxitalamate. Each tooth underwent CBCT before and after contrast application, followed by micro-computed tomography (micro-CT) as the reference standard. Two blinded observers recorded the number of cracks detected on CBCT and confirmed by micro-CT. Statistical analysis was performed using ANOVA with LSD post hoc comparisons. Micro-CT detected an average of 19.9 ± 9.3 cracks per tooth. On CBCT, ioversol and barium sulfate performed similarly (5.6 ± 2.3 and 5.8 ± 2.1 cracks, respectively), whereas meglumine ioxitalamate detected fewer (3.4 ± 1.7, p = 0.001). When matched against micro-CT, ioversol and barium sulfate detected ~ 4 cracks, while meglumine ioxitalamate detected fewer than 3. Barium sulfate detected the largest proportion of deep cracks (20.7%). Contrast-enhanced CBCT improves detection of fine cracks compared with unenhanced scans. Ioversol and barium sulfate demonstrated superior diagnostic value, while meglumine ioxitalamate offered limited benefit.
More Related Videos
10:23Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging