Intravenous contrast medium impairs CT-based muscle quality but not quantity assessment: a translational study
Luca Salhöfer1,2, Gregor Jost3, Mathias Holtkamp2
1Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Contrast-enhanced CT scans affect muscle radiodensity and intermuscular adipose tissue (IMAT) measurements in body composition analysis. Muscle and extramuscular fat volumes are reliably quantified across different contrast phases.
Area of Science:
- Radiology
- Medical Imaging
- Body Composition Analysis
Background:
- Computed Tomography (CT)-based body composition analysis (BCA) provides critical imaging biomarkers for muscle volume and quality.
- Clinical application of CT-BCA is hindered by concerns regarding the comparability of non-contrast and contrast-enhanced scans.
- Understanding the impact of contrast media (CM) on BCA is crucial for consistent clinical interpretation.
Purpose of the Study:
- To evaluate the influence of various contrast phases on volumetric CT-based body composition analysis.
- To assess the comparability of body composition metrics derived from non-contrast and contrast-enhanced CT scans.
Main Methods:
- 20 Göttingen minipigs underwent non-contrast (NC) and five contrast-enhanced CT scans at different phases.
- 114 tri-phasic human CT scans were analyzed for validation.
- A volumetric BCA network (BOA) extracted muscle radiodensity and volumes of muscle, subcutaneous adipose tissue (SAT), intermuscular adipose tissue (IMAT), visceral adipose tissue (VAT), and total adipose tissue (TAT).
Main Results:
- Contrast administration tended to reduce IMAT volumes and significantly increased muscle radiodensity in both animal models and human validation.
- Muscle radiodensity was significantly higher following CM administration (p < 0.001 in animals, p = 0.007 in humans).
- IMAT volume showed a tendency towards reduction with CM (p = 0.10 in humans), while muscle and extramuscular fat volumes remained robust.
Conclusions:
- Myosteatosis surrogates like muscle radiodensity and IMAT are susceptible to interference from contrast media.
- Volumetric quantification of muscle tissue and extramuscular adipose tissue (SAT, VAT, TAT) is robust across different contrast phases.
- Careful consideration of contrast effects is needed when interpreting CT-BCA, particularly for muscle quality metrics.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...