Related Experiment Video
Updated: May 26, 2026

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
Understanding Baseline Drift in Laser-Induced Graphene Electrodes and Its Impact on Heavy Metal Detection by Anodic
Kuo-Hao Chen1, Kamal Arora1, John Earwood2
1Department of Chemistry, University of Missouri-Columbia, Columbia, Missouri 65211, United States.
Abstract:
The planar Laser-Induced Graphene (LIG) patterned electrochemical sensor device was fabricated with a CO2 infrared laser on a commercial polyimide film. We investigated the dynamic surface and baseline current changes in LIG versus Glassy carbon (GC) electrodes after multiple square wave voltammetry (SWV) scans in 0.1 M acetate buffer (pH 4.5), using OCP and EIS techniques. Additionally, bismuth-film coated on LIG (Bi/LIG) and GC (Bi/GC) electrode were characterized and compared for detection of heavy metal ions using anodic stripping voltammetry (ASV). The electrochemical deposition and stripping processes of Pb, Cu, Zn and Cd on these Bi/LIG were studied to obtain mechanistic insights. Results show that the nature and condition of the LIG substrates have a profound effect upon the nucleation and growth of the bismuth deposit. A simple baseline correction strategy was used on LIG device for detection of multiple heavy metal ions (i.e. Pb2+, Cd2+, Cu2+ and Zn2+) in 0.1 M acetate buffer (pH 4.5) with square wave anodic stripping voltammetry (SWASV) and the corresponding limit of detections (LOD) are found to be 14.82 ppb (Zn2+), 12.11 ppb (Cd2+), 11.55 ppb (Pb2+), and 14.64 ppb (Cu2+) respectively. The Bi/LIG sensor device was further tested for metal analysis in a real-world sample. Results show that baseline correction provides accurate Pb2+ detection despite limitations towards other metal ions. LIG electrodes also provide better detection for Zn2+ and Cu2+ than GC electrode. This study provides the methods and mechanistic understandings for the use of porous and heterogeneous LIG materials in the analytical detection of multiple heavy metals.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Electrodeposition
Electrodeposition can...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Amperometry: Overview