Related Experiment Video
Updated: May 27, 2026

Automated Joint Space Detection Improves Bone Segmentation Accuracy
Published on: November 28, 2025
Automated assessment of coronal lower extremity alignment on long-leg radiographs using a deep-learning model:
Wenzhong Jin1,2, Xu Jiang2, Yushun Tao2
1School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China.
Purpose:
To develop, validate, and benchmark a fully automated deep learning (DL) system that simultaneously measures 15 coronal lower-limb alignment parameters on standing long-leg radiographs (LLRs) and localizes deformity, and to compare two tibial joint-line definitions for suitability in DL-based measurement.
Methods:
A retrospective set of 309 anteroposterior standing LLRs was split into training/validation/testing (60/20/20). External generalizability was assessed using 75 independent LLRs from a different scanner and patient cohort. YOLOv5 was used to detect multiple bony landmarks, followed by algorithmic calculation of 15 parameters (e.g., HKAA, mLDFA, mMPTA). Two tibial joint-line definitions were evaluated: Method 1 (line through medial/lateral lowest tibial plateau points) and Method 2 (line through most medial/lateral plateau edges). Accuracy, clinical failure rate (≥ 2° or ≥ 2%), and runtime were compared with expert consensus annotations. Bland-Altman analysis was added to assess measurement bias and clinical agreement.
Results:
On the external dataset, absolute errors for knee phenotype-related parameters ranged from 0.07° to 0.45°. Automated analysis of all 15 parameters took 24.3 ± 0.7 s, reducing time by 89-91% versus manual measurement (p < 0.001). Method 2 produced significantly smaller absolute errors than Method 1 for nearly all parameters (p ≤ 0.005). Clinically significant failure rates were low (0-4.7%) and were significantly lower than an attending physician's for several key metrics on the external set. The distribution of varus/valgus/neutral alignment based on HKAA and extraarticular deformity locations were reported.
Conclusion:
This DL framework provides fast, comprehensive, and specialist-level coronal alignment assessment on LLRs. An edge-based tibial joint-line definition (Method 2) outperforms a lowest-point definition, improving precision and reliability for DL measurement pipelines, supporting clinically deployable orthopedic imaging AI. Future prospective studies are warranted to validate Method 2 against clinical outcomes including osteoarthritis progression and surgical results.
Related Concept Videos
Bones of the Lower Limb: Tibia and Fibula
Bones of the Lower Limb: Femur and Patella