Related Experiment Video
Updated: May 28, 2026

Electronic Tongue Generating Continuous Recognition Patterns for Protein Analysis
Published on: September 16, 2014
XAI-Supported Electronic Tongue for Estimating Milk Composition and Adulteration Indicators
Ahmet Çağdaş Seçkin1, Murat Ekici2, Tolga Akcan3
1Department of Computer Engineering, Aydın Adnan Menderes University, 09010 Aydin, Türkiye.
None:
In this study, a low-cost AS7265x-based multispectral electronic tongue system was developed for estimating milk composition and adulteration indicators and supported with an explainable artificial intelligence (XAI) framework. Experimental analyses were conducted on 190 augmented commercial milk samples, where fat, protein, solids-not-fat (SNF), density, freezing point, and added water ratio were treated as target variables. Sensor data were modeled as RAW, DERIVED, and FUSION feature sets, and regression performance was compared using Random Forest, Gradient Boosting, AdaBoost, KNN, and XGBoost. Model validation was carried out with both five-fold cross-validation and Leave-One-Out (LOO) strategies to assess field-level generalizability. Results showed that a narrow-band, low-cost optical sensor platform can estimate not only fat and protein but also SNF, density, and freezing point with high accuracy. Within the XAI framework, permutation-based importance analysis and SHAP were used to identify critical spectral bands for each target parameter, enabling data-driven recommendations for band-oriented sensor design optimization. The study presents a scalable methodology that integrates low-cost sensor design, multi-parameter quality estimation, and explainable modeling beyond traditional fat-protein-focused approaches. Across all six targets, the XAI analysis consistently identified the near-infrared channel at 860 nm (asIR_3) as the most informative band, reflecting the combined effect of water absorption and Mie scattering by fat globules; the visible channel at 680 nm (asVIS_4) emerged as a secondary band, reflecting dissolved-matter scattering. These bands are therefore the natural starting point for cost-reduced versions of the sensor. Among the compared feature sets (RAW, DERIVED, FUSION), the 18-band RAW configuration provided the most balanced performance across all six targets.
Related Concept Videos
Automated Microbial Diagnostics
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...