Related Experiment Video
Updated: May 28, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
A Practical Weakly Supervised Framework for Dose-Up Translation of Low-Enhanced CT Under Clinical Acquisition
Jong Bub Lee1, Se Hwan Lim2,3, Yu Jin Jung4
1Department of Electrical and Computer Engineering, Inha University, 100 Inha-ro, Incheon 22212, Republic of Korea.
None:
Low-dose contrast-enhanced computed tomography (CT) is widely used to reduce contrast-induced toxicity, but reduced iodine concentration and inconsistent acquisition conditions often produce uneven contrast attenuation and spatial misalignment between scans. In this context, we define dose-up translation as the computational process of synthetically enhancing low-dose contrast images to approximate the visual and diagnostic quality of full-dose acquisitions. These factors limit the effective use of routinely acquired imaging data for dose-up translation, particularly in veterinary abdominal CT where respiratory motion and postural variability further degrade anatomical correspondence. We present a weakly aligned enhancement framework designed to operate under spatial misalignment and limited paired data. Registration-based pseudo-references are constructed using a hybrid strategy that combines deformable anatomical alignment with feature-level correspondence. Dose-up translation is performed using structure-preserving translation with multi-scale consistency and edge-aware regularization to maintain anatomical boundaries. To address limited low-dose datasets, a two-stage knowledge transfer strategy transfers anatomical and contrast priors from abundant pre-contrast data. Quantitative evaluation demonstrated region-level contrast-to-noise ratio improvements of up to 31.5% (e.g., from 5.55 to 8.38 in the caudal vena cava (CVC), p < 0.05) compared with baseline enhancement methods across 1171 test slices. Experiments demonstrate consistent improvements in structural fidelity, distributional realism, and region-level vascular conspicuity compared with paired, unpaired, and synthetic-pairing baselines. These findings suggest that the dose-up translation of low-enhanced CT is better formulated as a weakly aligned domain adaptation problem rather than a strictly paired reconstruction task, enabling practical image translation under realistic clinical acquisition variability.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT