Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Optimal PEEP Obtained by Titrating Inspiratory Oxygen Fraction Versus Electrical Impedance Tomography in Patients
Lingling Gao1,2, Lili Pan1,2, Li Yang1,2
1Department of Anesthesiology, Fudan University Shanghai Cancer Center, Shanghai 200032, China.
Background:
The optimal intraoperative positive end-expiratory pressure (PEEP) obtained by titrating to the lowest tolerable fraction of inspired oxygen (FiO2) has been proposed recently; however, whether its performance in obtaining optimal PEEP is comparable to that from electrical impedance tomography (EIT) titration remains unknown.
Methods:
Ninety-three adult patients undergoing robotic-assisted laparoscopic prostatectomy under general anesthesia were enrolled in this study. They underwent the determination of optimal PEEP obtained either by titrating to the lowest tolerable FiO2 (PEEPO2) or using EIT (PEEPEIT). The primary endpoint was intraoperative optimal PEEP values. Secondary endpoints included pre-extubation arterial oxygen partial pressure (PaO2)/FiO2, intraoperative mean arterial blood pressure (MAP), the incidence of hypoxemia in the postanesthesia care unit (PACU), and postoperative pulmonary complications (PPCs) up to discharge from hospital.
Results:
Group PEEPO2 (n = 47) exhibited a higher optimal PEEP compared to Group PEEPEIT (n = 46) [Median (IQR): 18 (16-18 cmH2O) vs. 16 (14-16 cmH2O), p < 0.001]. Pre-extubation PaO2/FiO2 was higher in Group PEEPO2 (510.5 ± 80.0 vs. 471.8 ± 69.0 mmHg, p = 0.015), while lung dynamic compliance (41.1 ± 7.7 vs. 37.3 ± 6.4 mL cmH2O-1, p = 0.011) and static compliance (36.4 ± 5.8 vs. 33.6 ± 5.5 mL cmH2O-1, p = 0.017) were also higher in Group PEEPO2. Additionally, driving pressure (11.0 ± 2.0 vs. 12.1 ± 1.9 cmH2O, p = 0.006) was lower in Group PEEPO2. There were no significant differences in intraoperative MAP and the incidences of PACU hypoxemia and PPCs between the two groups.
Conclusions:
The optimal PEEP obtained by titrating to the lowest tolerable FiO2 is a clinically acceptable alternative of that obtained using EIT. Therefore, this technique could be a viable alternative to EIT for obtaining optimal PEEP.
Related Concept Videos
Atelectasis II: Pathophysiology
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: