Related Experiment Video
Updated: May 28, 2026

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Research on the Axial Compression Performance of Double C-Section Partially Encased Composite Columns
Ming Zhou1, Linglin Qin1, Xiaodong Wen1
1School of Architecture and Transportation Engineering, Ningbo University of Technology, Ningbo 315211, China.
Abstract:
To investigate the axial compressive behavior of double C-section partially encased composite (DCPEC) columns, 10 DCPEC specimens and two back-to-back bare steel C-section specimens were designed and tested under axial compression. The effects of key parameters, including steel wall thickness, member slenderness ratio, connection type of the built-up double C-sections and connection density, on the failure mode, load-displacement response and ultimate load-carrying capacity were examined. The test results showed that, under otherwise identical conditions, the ultimate load of the bolted stub column was 8.4% higher than that of the welded stub column. When the steel wall thickness increased from 2.0 mm to 3.0 mm, the ultimate load increased by approximately 16%. In contrast, when the slenderness ratio increased from 25.98 to 41.57, the ultimate load decreased by approximately 30%. A finite element model was then established in ABAQUS and validated against the experimental results. The numerical analysis further confirmed that increasing the slenderness ratio reduced the axial load-carrying capacity, whereas increasing the steel wall thickness improved the resistance of the member. The results indicate that the proposed DCPEC column can effectively develop the composite action between cold-formed thin-walled steel and lightweight aggregate concrete, thereby improving axial resistance and showing promising potential for engineering applications.
Related Concept Videos
Design of Columns under an Eccentric Load
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...
Eccentric Axial Loading in a Plane of Symmetry
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Eccentric Loading
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...