Related Experiment Video
Updated: May 28, 2026

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature
Alireza Tabrizikahou1, Jan Białasik1, Karol Nowak2
1Institute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland.
None:
Iron-based shape memory alloy (Fe-SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe-SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe-SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe-SMA activation in cracked UHPFRC members.
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55 °C.
Temperature Dependent Deformation
Design of Prismatic Beams for Bending
Thermal Strain
Reinforcements in Concrete
Mass Concreting
To reduce the risk of such cracking, the concrete mix may incorporate low-heat cement and pozzolans to reduce the temperature rise. Pre-cooled angular aggregates and water-reducing admixtures...

