Related Experiment Video
Updated: May 29, 2026

Non-Intubated Video-Assisted Thoracoscopic Surgery
Published on: May 26, 2023
Safety of Depth-Adjusted Intravenous Anesthesia in Office-Based Aesthetic Surgery: A One-Month Prospective Study of
Keisuke Matsumura1, Takahiko Tamura2, Kohki Okumura2
1TCB Umeda Osaka Ekimae Clinic, Tokyo Chuo Beauty Clinic K's Square, Building 3F, 2-8-15 Sonezaki, Kita-ku, Osaka-City, Osaka, 530-0057, Japan. dr.matsumura.keisuke@tcb.or.jp.
Background:
Office-based aesthetic surgery frequently relies on intravenous anesthesia to balance intraoperative comfort with rapid recovery. While large series suggest low complication rates, prospective data on patient-reported outcomes under standardized, depth-adjusted protocols remain limited. This study prospectively evaluated safety, satisfaction, recall, and recovery using the specialist-led UMEDA protocol.
Methods:
In a single-center, prospective observational study, all consecutive adults undergoing office-based aesthetic procedures between May 1-31, 2025 were analyzed (N = 135). Intravenous anesthesia followed the UMEDA (Ultra-safe Method for Elective Depth-adjusted Anesthesia) protocol; monitoring included automated noninvasive blood pressure, heart rate, and pulse oximetry at 5-min intervals. Anesthesia was predominantly propofol-based (133/135), with midazolam used only in patients with a history of allergy to propofol formulation components (2/135). Primary endpoint was patient satisfaction (5-point Likert). Secondary endpoints were intraoperative recall, recovery time, and major cardiorespiratory events. Two prespecified multivariable logistic regressions examined predictors of (1) high satisfaction (score = 5) and (2) continuous recall.
Results:
No major cardiorespiratory events occurred. Median satisfaction was 5 [IQR 4-5]; 68.1% rated 5. Intraoperative recall was "none" in 38.5%, "induction/emergence only" in 47.4%, and "continuous" in 14.1%. Median recovery time was 22 min [13.0-36.0]. In the satisfaction model, female sex independently predicted high satisfaction (aOR 3.31; 95% CI 1.04-10.50; p = 0.042); age, operative time, recovery time, weight-adjusted propofol dose, multiple procedures, and continuous infusion were not significant (all VIF<5). In the recall model, higher weight-adjusted propofol dose independently reduced the odds of continuous recall (aOR 0.07; 95% CI 0.01-0.67; p = 0.021); sex was not significant (all VIF < 2).
Conclusions:
In 135 consecutive office-based cases managed with the UMEDA protocol, depth-adjusted intravenous anesthesia was delivered safely with very high satisfaction, low rates of persistent intraoperative recall, and rapid recovery. These findings support safe and effective implementation of specialist-led, depth-adjusted intravenous anesthesia in ambulatory aesthetic practice and motivate multicenter validation.
Level Of Evidence Iv:
This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Parenteral Anesthetics: Overview
Local Anesthetics: Clinical Application as Spinal Anesthesia
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
