Related Experiment Video
Updated: May 29, 2026

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Development and validation of a cuff size prediction model for pediatric blood pressure measurement outside the
James T Nugent1,2,3, Victoria Cueto4, Hugh Medvecky5
1Section of Pediatric Nephrology, Department of Pediatrics, Yale School of Medicine, 60 Temple Street, Suite 6C, New Haven, CT, 06510, USA. james.nugent@yale.edu.
Background:
Mid-arm circumference (AC) is typically measured in person to determine cuff size for ambulatory blood pressure monitoring (ABPM). Our objective was to develop a model to predict cuff size using electronic health record (EHR) data to enable virtual ABPM programs.
Methods:
We developed a prediction model for youth 3-21 years in the National Health and Nutrition Examination Survey. Using linear regression, we considered piecewise and polynomial effects of age, sex, height, and weight as predictors of AC. We selected the model with the lowest bootstrapped root-mean-square error (RMSE) and predicted residual error sum of squares with leave-one-out cross-validation. We validated the model in pediatric hypertension clinics at an academic medical center.
Results:
Based on 34,517 youth in the derivation cohort (median 12 years (25th, 75th percentiles: 7, 16), 49.0% female, 16.6% obesity), the final model included age, age2, sex, height, weight, weight2, weight3, and all possible interactions between age and height and between age and weight (adjusted R2, 0.97; RMSE, 1.20). In the external validation cohort of 107 youth (median 14 years (25th, 75th percentiles: 10, 17), 35.5% female, 61.7% obesity), observed and predicted AC were highly concordant (⍴c, 0.94) with mean bias of -0.5 cm (95% limits of agreement, -5.2; 4.1). Overall agreement for the correct cuff size was 87.5% in the derivation cohort (weighted κ, 0.92) and 83.2% in the validation cohort (weighted κ, 0.90).
Conclusions:
We found substantial agreement between observed and predicted AC using basic EHR data. This model may facilitate ABPM when in-person visits are not feasible.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...