Non-Invasive Evaluation of Pulmonary Artery Stenosis in Congenital Heart Disease Patients Using Phase Contrast MRI
Rupak K Banerjee1, Gavin A D'Souza2, Shreyash M Manegaonkar2
1Department of Biomedical Engineering, University of Cincinnati, 593 Rhodes Hall, Cincinnati, OH, 45221, USA. Rupak.Banerjee@uc.edu.
Background:
Branch pulmonary artery (PA) stenosis is a significant congenital heart defect causing elevated pulmonary blood pressure, trans-stenotic pressure drop, and abnormal differential blood flow to the lungs. We propose combined pressure-flow diagnostic parameters, pressure drop coefficient (CDP) and normalized energy loss (Ēloss) for improved delineation of stenosis severity. In extension to our previous benchtop experimental study, we performed in vitro experiments using phase contrast magnetic resonance imaging (PC MRI) to evaluate the diagnostic parameters and stenosis severity non-invasively.
Methods:
Subject-specific branch PA test sections representing the main, left, and right PAs (MPA, LPA, and RPA) with a discrete LPA stenosis were manufactured from medical images using additive manufacturing. Three clinically-relevant stenosis severities, 70% area stenosis (AS), 80% AS, and 90% AS, were evaluated at 2 LPM cardiac output under pathophysiologic hemodynamics generated using a mock circulatory loop. 2D (all severities) and 3D (only 70% AS) PC MRI scans were performed to compute the velocity (or flow) and derived pressure drop across the PA test section. The CDPLPA and were evaluated for the three stenosis severities using MRI measurements and compared against results from the benchtop study.
Results:
The CDPLPA increased with an increase in LPA stenosis severity [70% AS: 11 (2D PC), 11.5 (3D PC); 80% AS: 34.6; 90% AS: 154.2]. These values resulted in an absolute difference of within 107 (2D PC) and 3 (3D PC) compared to the benchtop values. Interestingly, the CDPLPA computed by all three methods (benchtop, 2D and 3D PC MRI) showed distinct and non-overlapping ranges for each stenosis severity [70% AS: 11.0-14.5; 80% AS: 34.6-60.7; and 90% AS: 154.2-261.6]. The (absolute) generally increased with an increase in LPA stenosis severity, except for 90% [70% AS: - 435 mJ per QLPA (2D PC), - 376 mJ per QLPA (3D PC); 80% AS: - 945 mJ per QLPA; 90% AS: - 933 mJ per QLPA (QLPA-LPA flow rate)].
Conclusions:
The CDPLPA demonstrates an improved diagnostic capability over in accurately delineating unilateral PA stenosis severity. Further, PC MRI is a comprehensive and safe clinical modality for the non-invasive diagnosis of branch PA stenosis.
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT