Related Experiment Video
Updated: May 31, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Controlled sweat generation via ultrasound stimulation integrated in a wearable device
Litong Chen1, Benxing Su1, Geng Zhong1
1College of Chemistry and Environmental Engineering, Synthetic Biology Research Center of Shenzhen University, Institute for Advanced Study, Shenzhen University, Shenzhen, Guangdong, 518060, PR China.
Abstract:
Wearable sweat biosensors enable noninvasive molecular monitoring, but reliable and comfortable on-demand sweat induction remains challenging. We developed a soft, skin-conformal wearable device that integrates ultrasound-assisted sweat generation with electrochemical sensing. Low-frequency ultrasound enhanced transdermal delivery of carbachol from a hydrogel reservoir, inducing localized sweat secretion under resting conditions without electrical current or skin penetration. Under the matched 15-min experimental window used here, ultrasound-induced sweating showed lower observed skin irritation and more favorable user-rated comfort than the tested iontophoresis setting. Integrated sensors measured uric acid, pH and K+ in ultrasound-induced sweat, and sweat uric acid showed a positive correlation with serum levels in a preliminary human study. These results support wearable ultrasound as a low-irritation strategy for controlled sweat generation and downstream biomarker tracking under resting conditions.
More Related Videos
Related Concept Videos
Accessory Structures of the Skin: Sweat Glands
Sweat glands are classified as merocrine glands; that is, the secretions are excreted by exocytosis through a duct without affecting the cells of the gland. There...
Body Temperature
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...