Assessing Image Quality and Diagnostic Performance of Quadruple-Low Coronary CT Angiography with Deep Learning in
Ke Qi1, Shumeng Li1, Luotong Wang2
1The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan 450052, China (K.Q., S.L., J.Z., X.W., P.H., D.Y., Y.Z., A.D., Q.T., M.Z., W.Z., J.G., J.L.).
Rationale And Objectives:
To examine the feasibility of a quadruple-low protocol in coronary computed tomography angiography (CCTA) assisted by the deep learning image reconstruction (DLIR) for participants with high body mass index (BMI).
Materials And Methods:
This prospective study involved 180 participants (BMI of ≥ 25 kg/m2). Participants were randomly assigned to three groups: the standard-dose (SD) group in 100 kVp with adaptive statistical iterative reconstruction (ASIR-V 50%) using contrast media (CM) administration at an iodine load of 245 mgI/kg (Iohexol, 350 mgI/mL) with a 10 s injection time; the experimental group underwent imaging with 80 kVp and DLIR-H, using an iodine load of 128 mgI/kg with a 7 s injection time, representing the triple-low (TL) with 350 mgI/mL Iohexol and quadruple-low (QL) groups with 320 mgI/mL Iodixanol. Quantitative image quality evaluations included vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR), while qualitative image quality and diagnostic performance were also assessed.
Results:
Compared to the SD group, the TL group achieved reductions of 29.4% in radiation dose, 47.5% in CM volume, and 23.5% in CM injection rate, while the QL group achieved reductions of 32.5% in radiation dose, 41.5% in CM volume, 14.5% in CM injection rate, and 9% in CM concentration. The image noise in the QL and TL groups were significantly lower than in the SD group (all p < 0.001). Overall, the SNR, CNR, and qualitative image quality of the TL and QL groups were superior to those of the SD group (p < 0.05). The QL group maintained the stenosis diagnostic performance (all p > 0.05).
Conclusion:
TL and QL CCTA protocols showed equivalent or superior image quality and diagnostic accuracy compared to the SD protocol and may serve as effective alternatives for reducing radiation dose and contrast media use in patients with high BMI.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...