Investigating Setup Error Differences between Conventional and Ultra-Hypofractionated Whole Pelvis Radiation Therapy:
Bryan Schaly1,2, Lucas C Mendez1, Maha Khawaja2,3
1Department of Radiation Oncology, London Health Sciences Centre, London, Ontario, Canada.
Journal of Applied Clinical Medical Physics
|June 1, 2026
Summary
Ultra-hypofractionated radiotherapy showed smaller setup errors for the prostate clinical target volume (CTVp) compared to conventional fractionation. However, nodal clinical target volume (CTVn) margins may need adjustment in ultra-hypofractionated regimens.
Area of Science:
- Radiation Oncology
- Medical Physics
- Prostate Cancer Treatment
Background:
- The HOPE trial (NCT04197141) evaluated conventional versus ultra-hypofractionated whole pelvis radiotherapy for high-risk prostate cancer patients receiving brachytherapy boost.
- Setup errors for prostate (CTVp) and nodal (CTVn) clinical target volumes were investigated within this randomized controlled trial.
Purpose of the Study:
- To compare setup errors between conventional and ultra-hypofractionated radiotherapy regimens in prostate cancer patients.
- To determine appropriate planning target volume (PTV) margins based on quantified setup uncertainties for both treatment arms.
Main Methods:
- Fifty-four patients (28 ultra-hypofractionated, 26 conventional) were analyzed from a single institution.
- Fiducial markers in the prostate enabled daily cone-beam CT (CBCT) matching; nodal errors were assessed via bone matching.
- Asymmetric PTV margins were calculated using the van Herk formalism to account for measured setup errors.
Main Results:
- Statistically significant reductions in 3D setup errors were observed for CTVp in the ultra-hypofractionated arm (1.2 mm) versus conventional (1.4 mm).
- No significant difference in CTVn setup errors was found between the two arms (2.9 mm vs. 2.8 mm).
- Required PTV margins varied by direction, with slightly larger margins needed for nodal CTVs, particularly in the ultra-hypofractionated arm.
Conclusions:
- A 6-mm PTV margin for CTVn appears adequate, but CTVp margins might be reducible in ultra-hypofractionated regimens if other errors are controlled.
- Smaller prostate setup errors in the ultra-hypofractionated arm may relate to longer image matching times or increased use of 6-DOF couches.
- Centers must independently assess treatment uncertainties, as differences were observed between arms despite standardized protocols.