Related Experiment Video
Updated: Jun 4, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
A manganese bath system for reliable neutron emission rate measurements
Khaled Mostafa1, Mohamed A Elsaied2, A Abdelsalam3
1Ionizing Radiation Metrology Lab., National Institute of Standards, Giza, Egypt.
Abstract:
A complete Mn-bath system was installed at the Ionizing Radiation Metrology Laboratory (IRML), National Institute of Standards (NIS), Egypt. The system consisted of a stainless-steel sphere with a diameter of 1 m and a thickness of 5 Cm. An americium-Beryllium (Am-Be) neutron source with 3.7 × 1010 Bq activity was immersed in a Mn-bath that is filled with MnSO4 solution. Gamma and neutron doses were measured outside the bath and were compared with the results calculated using Monte Carlo MCNP simulations. Different molarity of MnSO4 was used, up to 0.91 mol/L. Required correction factors were determined analytically using neutron cross-sections for Sulfur, Oxygen, and Hydrogen elements, and by MCNP. An agreement between the experimental measurements of the neutron source emission rate and that obtained by MCNP was found; this agreement was enhanced with increasing MnSO4 molarity up to 0.91 mol/L. Furthermore, the uncertainty of the emission rates was calculated, and it was found to decrease with increasing molarity.