Related Experiment Video
Updated: Jun 4, 2026

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
Environmental footprint of peritoneal dialysis in Europe: a comparative life cycle assessment across four European
Abass Fehintola1, Zuzanna Jakubowska2, Malgorzata Kepska-Dzilinska2
1School of Dental, Child and Public Health,Trinity College Dublin, Dublin, Ireland.
Introduction:
Peritoneal dialysis (PD) is a home-based renal replacement therapy offering clinical and quality-of-life advantages, but it also poses environmental challenges due to resource use and waste generation. This study compares the environmental impacts of PD across four European centres to identify regional sustainability differences and evaluate the footprint of continuous ambulatory (CAPD), automated (APD), and incremental (iPD) PD.
Methods:
A cradle-to-grave life cycle assessment (LCA) was conducted for one year of PD treatment per patient using OpenLCA software and the EcoInvent database across four clinical centres; Madrid, Warsaw, Utrecht, Modena. Data were collected on material use, energy and water consumption, transportation, and waste disposal. Key indicators included global warming potential (GWP), energy use, water footprint. The environmental performance of each centre and dialysis modality was assessed.
Results:
Environmental impacts varied significantly between centres ranging from GWP 3381 kg CO₂-eq to 1736 kg, reflecting differences in energy mix and efficiency. Energy consumption ranged from 54,710 MJ to 28,894 MJ and water footprint from 6631 m³ to 854 m³. Across all centres, CAPD and APD had higher environmental burdens than iPD. iPD reduced emissions by up to 50% and had a lower-impact profile.
Conclusions:
PD displays substantial environmental impact variability across centres, driven by differences in material consumption, waste management, energy sourcing, and clinical protocols. Cleaner energy profiles, effective waste management, and reduced reliance on single-use consumables may lower environmental burdens. These findings underscore the importance of integrating environmental performance into clinical decision-making and health system planning.
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Peritoneal Dialysis III: Nursing Management
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis