Comparative outcomes of intra-aortic balloon pump versus impella in non-myocardial infarction cardiogenic shock: A

Omar Khalil1, Arwa Saed Aldien1, Peng Cai2

  • 1Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA.

JHLT Open
|June 3, 2026
PubMed

Insights

High-flow Impella 5.0/LD/5.5 devices improved survival and advanced therapy rates in non-myocardial infarction cardiogenic shock (non-MI CS) patients compared to intra-aortic balloon pumps (IABPs). Low-flow Impella 2.5/CP devices showed worse outcomes than IABPs.

Area of Science:

  • Cardiology
  • Mechanical Circulatory Support
  • Critical Care Medicine

Background:

  • Cardiogenic shock (CS) management often involves mechanical support devices.
  • Intra-aortic balloon pumps (IABPs) and percutaneous left ventricular assist devices (pLVADs, Impella) are commonly used.
  • Evidence for non-myocardial infarction (non-MI) CS, especially with newer Impella models, is limited.

Purpose of the Study:

  • To compare the outcomes of IABP versus various Impella devices in patients with non-MI CS.
  • To evaluate the effectiveness of different Impella models (2.5/CP vs. 5.0/LD/5.5) in non-MI CS.

Main Methods:

  • Retrospective analysis of National Inpatient Sample (NIS) data from 2016-2022.
  • Inclusion of patients diagnosed with non-MI CS who received IABP, Impella 2.5/CP, or Impella 5.0/LD/5.5.
  • Comparison of in-hospital mortality, rates of orthotopic heart transplant (OHT) and durable left ventricular assist device (LVAD) implantation, transfusion requirements, length of stay, and hospital charges.

Main Results:

  • Impella 5.0/LD/5.5 use was linked to lower mortality (8.2% vs. 14.9%), higher OHT (27.6% vs. 11.7%) and LVAD rates (45.1% vs. 15.6%) compared to IABP, but with longer stays and higher charges.
  • Impella 2.5/CP use was associated with higher mortality (39.6% vs. 23.6%) and lower OHT/LVAD rates than IABP, alongside shorter stays and lower charges.
  • Significant differences (P<0.05) were observed across all compared outcomes between device groups.

Conclusions:

  • In non-MI CS, high-flow Impella 5.0/LD/5.5 devices demonstrated improved survival and advanced therapy rates over IABP.
  • Low-flow Impella 2.5/CP devices were associated with worse outcomes than IABP in non-MI CS.
  • While Impella 5.0/LD/5.5 offered benefits, it also resulted in increased resource utilization, including transfusion needs and hospitalization duration.