Suspected venous oxygen embolism following hydrogen peroxide wound irrigation causing intraoperative asystole
Muhammad Azhar Sharafat1, Zohair Ahmed Khan2, Muhammad Sohaib2
1Anaesthesia, The Aga Khan University Hospital, Karachi, Pakistan m.azhar92@hotmail.com.
Abstract:
A man in his 20s underwent wound debridement and external fixation for a femoral fracture sustained in a blast injury. Anaesthesia was induced with propofol and nalbuphine and the airway was secured with an i-gel laryngeal mask. About 45 min after induction, irrigation of the semiclosed wound with hydrogen peroxide was followed by a sudden fall in end-tidal carbon dioxide and tachycardia, which progressed rapidly to asystole. Cardiopulmonary resuscitation was started immediately, and tracheal intubation was performed during the first cycle of compressions. Return of spontaneous circulation occurred 6 min later. The patient recovered fully with no neurological or cardiovascular sequelae. The close temporal link between hydrogen peroxide irrigation and circulatory collapse was suggestive of intraoperative oxygen embolism, likely facilitated by oxygen liberation in a confined cavity. This case highlights the need to limit or avoid the use of hydrogen peroxide as irrigant whenever possible, and exercise caution and preparedness whenever its use becomes unavoidable.
Related Concept Videos
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Aneurysm IV: Nursing Management
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care