Purpose:
This study aimed to evaluate the feasibility of equilibrium contrast-enhanced dual-energy computed tomography (DECT) compared with tumor single-energy CT (SECT) to calculate the extracellular volume (ECV) fraction for differentiation between benign and malignant renal masses.
Methods:
The sample included 77 patients with renal masses who underwent DECT between March 2019 and July 2021. Unenhanced and 120-kVp equivalent images were used to calculate tumor SECT-derived ECV fractions. Iodine density images were obtained from equilibrium-phase DECT for calculating DECT-derived ECV fractions. Relationships between SECT- and DECT-derived ECV fractions were examined by Pearson correlation analysis. Consistency between the SECT- and DECT-derived ECV fractions was evaluated using the intraclass correlation coefficient and Bland-Altman analyses. The discrimination performance of ECV for malignant and benign renal masses was compared using the independent sample t-test and receiver operating characteristic curve analysis.
Results:
The SECT- and DECT-derived ECV fractions were strongly correlated ( r = 0.756, P < 0.001). The Bland-Altman plot of the SECT- and DECT-derived ECV fractions revealed a small bias (-1.6%). The ECV fraction was significantly higher for malignant renal masses than for benign masses (SECT, P < 0.001; DECT, P < 0.001). The area under the curve of DECT-ECV and SECT-ECV was 0.948 and 0.921, respectively. The sensitivity of DECT-ECV and SECT-ECV was 93.65% and 90.48%, respectively, while the specificity was 85.71% and 85.71%, respectively.
Conclusions:
Our findings show good correlation between DECT-ECV and SECT-ECV. The ECV fraction determined by equilibrium contrast-enhanced DECT is a potential new imaging marker for differentiating malignant from benign renal masses.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...