Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
NMR Spectrometers: Overview01:20

NMR Spectrometers: Overview

NMR spectrometers consist of a strong magnet, a radiofrequency transmitter, and a detector attached to a computer console for recording spectra of samples containing NMR-active nuclei. In first-generation NMR instruments called continuous-wave spectrometers, the resonance frequencies of the nuclei are determined by frequency-sweep or field-sweep methods. The magnetic field strength is fixed and the rf signal is swept in the former, while the radiofrequency signal is fixed and the magnetic field...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
NMR Spectroscopy: Chemical Shift Overview01:15

NMR Spectroscopy: Chemical Shift Overview

The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Efficient <sup>15</sup>N hyperpolarization of [<sup>15</sup>N<sub>3</sub>]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH.

Journal of magnetic resonance open·2026
Same author

Estimating the Sodium Content: A Case Series of Benign and Malignant Renal Tumours Using <sup>23</sup>Na-MRI at 3 T.

NMR in biomedicine·2026
Same author

Surface tension measurements reveal charge-driven surfactant depletion in microdroplets approaching the Rayleigh limit.

Chemical science·2026
Same author

Co-Contamination and Combined Effects of Microplastic and Microbial Load on Water Quality and Public Health Risks in Industrial and Urban Canals of Coastal Bangladesh.

Environmental health insights·2026
Same author

Decitabine Induces Subtype-Specific Epigenomic Remodeling and Perturbs Age-Associated Regulatory CpGs in Breast Cancer.

Cancer informatics·2026
Same author

Correction to "Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1-<sup>13</sup>C]Pyruvate".

ACS sensors·2026
Same journal

Biodegradable Self-Powered Electrotherapy Patch for Integrated Smart Wound Management.

Analytical chemistry·2026
Same journal

Metabolite Fraction Libraries for Quantitative NMR Metabolomics.

Analytical chemistry·2026
Same journal

Self-Contained Lateral-Flow Microfluidic Bead-Based Assay for Rapid Quantification of Early-Stage Kidney Biomarkers.

Analytical chemistry·2026
Same journal

Overcoming the Debye Shielding Effect with Concave-Convex Structures for Sensitivity-Enhanced Thin-Film Transistors.

Analytical chemistry·2026
Same journal

Mode-Phase-Difference Photothermal Spectroscopy Assisted by a Bent Biconically Tapered Microfiber for Gas Sensing.

Analytical chemistry·2026
Same journal

Negative-Pressure-Actuated Microfluidics: A Dual-Mode Point-of-Care Sensor for Allergen-Specific IgE in Interstitial Fluid.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: Jun 6, 2026

High-Pressure NMR Experiments for Detecting Protein Low-Lying Conformational States
04:37

High-Pressure NMR Experiments for Detecting Protein Low-Lying Conformational States

Published on: June 29, 2021

Correction to "Low-Cost Purpose-Built Ultra-Low-Field NMR Spectrometer"

Md Raduanul H Chowdhury, Firoz Ahmed, Clementinah Oladun

    Analytical Chemistry
    |June 5, 2026
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
    14:55

    Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy

    Published on: September 17, 2017

    15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the &#181;s-ms Timescale
    08:09

    15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale

    Published on: April 19, 2021

    Related Experiment Videos

    Last Updated: Jun 6, 2026

    High-Pressure NMR Experiments for Detecting Protein Low-Lying Conformational States
    04:37

    High-Pressure NMR Experiments for Detecting Protein Low-Lying Conformational States

    Published on: June 29, 2021

    Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
    14:55

    Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy

    Published on: September 17, 2017

    15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the &#181;s-ms Timescale
    08:09

    15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale

    Published on: April 19, 2021