Related Experiment Video
Updated: Jun 7, 2026

Processing of Bulk Nanocrystalline Metals at the US Army Research Laboratory
Published on: March 7, 2018
STEM in an SEM: Towards high-throughput imaging and analysis of metal nanoclusters
Yifan Chen1, Michael W Fay2, Wolfgang Theis3
1School of Chemistry, University of Nottingham, University Park, UK.
Abstract:
Accurately characterising metal nanoclusters is critical for advancing catalysis and energy conversion. While aberration-corrected scanning transmission electron microscopy (AC-STEM) achieves unmatched spatial resolution, its overall workflow throughput is often limited by instrument setup, alignment, and acquisition requirements. In contrast, scanning electron microscopy (SEM) offers higher throughput, but conventional SEM lacks sufficient spatial resolution for ultrasmall clusters of atoms. Here, we introduce a correlative imaging approach combining AC-STEM with high-angle annular dark-field (HAADF) STEM performed within an SEM (STEM-in-SEM), in particular using advanced in-lens field-emission SEM systems which offer the simplicity and ease-of-use of an SEM platform while retaining very high spatial resolution, to enable efficient and scalable metal nanocluster imaging and quantification workflows. Using platinum nanoclusters supported on graphene oxide as a model system for validation, identical-location imaging was employed to benchmark STEM-in-SEM against AC-STEM, eliminating the influence of sample polydispersity. Both techniques rely on the same incoherent HAADF imaging principle, and despite lower acceleration voltage and different detector geometry, STEM-in-SEM yields comparable intensity distributions. A comparison between STEM-in-SEM and AC-STEM demonstrated consistent intensity scaling. A reproducible and calibratable relationship between the number-of-atoms and image intensity can be established under STEM-in-SEM conditions. In this work, STEM-in-SEM is used to reliably quantify nanoclusters containing as few as ∼45 Pt atoms or nanoclusters with effective diameters down to ∼0.95 nm. Accordingly, a calibrated STEM-in-SEM image can be employed as a quantitative reference for other datasets imaged under the same conditions, provided that variations in specimen thickness and background contrast are sufficiently small to preserve consistent intensity scaling. By combining adequate spatial resolution and operational flexibility, STEM-in-SEM represents a practical and cost-effective complement to AC-STEM. Continued optimisation of imaging conditions, detectors, and automated analysis pipelines will further advance the broader applicability of this methodology in large-scale catalyst screening and nanomaterials discovery.
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Immunogold Electron Microscopy
Preparation of Samples for Electron Microscopy
Overview of Electron Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

