Fixation method does not influence functional outcomes after thumb metacarpophalangeal arthrodesis
Alyssa R Henriquez1, Chanel R Varney2, John Mwangi1
1Department of Orthopaedic Surgery, Duke University Health System, USA.
The Journal of Hand Surgery, European Volume
|June 6, 2026
Summary
Thumb metacarpophalangeal arthrodesis using plate, screw, or Kirschner wire fixation shows similar outcomes. Kirschner wire with tension band fixation had more hardware removals, impacting thumb joint fusion success.
Area of Science:
- Orthopedic surgery
- Hand surgery
- Surgical techniques
Background:
- Thumb metacarpophalangeal (MCP) arthrodesis is a surgical procedure to fuse the thumb's basal joint.
- Various fixation methods exist, including plates, screws, and Kirschner wires (K-wires) with or without tension bands.
- This study compares functional outcomes and complications across different fixation techniques for thumb MCP arthrodesis.
Purpose of the Study:
- To evaluate and compare range of motion, complications, and patient-reported outcomes (PROs) after thumb MCP arthrodesis using distinct fixation methods.
- To identify if specific fixation techniques are associated with better or worse functional results and complication rates.
Main Methods:
- Retrospective review of 106 patients undergoing thumb MCP arthrodesis at a single institution (2013-2025).
- Fixation techniques analyzed: plate, screw, K-wires with tension band, and K-wires alone.
- Outcomes measured: range of motion, Visual Analogue Scale (VAS) pain, Patient-Reported Outcome Measurement Information System (PROMIS) scores, and complications.
Main Results:
- No statistically significant differences in range of motion, PROMIS scores, or VAS pain scores were observed among the fixation groups.
- Complication rates were comparable across techniques, with the exception of hardware removal, which was highest (27%) in the K-wire with tension band group.
- Nonunion rates were low and did not vary significantly based on the fixation method used.
Conclusions:
- Thumb MCP arthrodesis yields similar functional and patient-reported outcomes regardless of the fixation technique employed.
- Kirschner wire fixation with tension bands is associated with a higher incidence of hardware removal compared to other methods.
- The choice of fixation may influence the need for subsequent hardware removal, though overall fusion success and function remain comparable.