Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
Deep learning-driven inversion framework for shear modulus estimation in magnetic resonance elastography
Hassan Iftikhar1,2, Rizwan Ahmad3,4, Arunark Kolipaka3,5,4
1Biomedical Engineering, The Ohio State University, Columbus, OH, USA. iftikhar.15@buckeyemail.osu.edu.
Purpose:
The multimodal direct inversion (MMDI) algorithm is widely used in magnetic resonance elastography (MRE) to estimate tissue shear stiffness but relies on the Helmholtz equation, which assumes a uniform, homogeneous, and infinite medium. Its use of the Laplacian operator also makes it highly sensitive to noise. This study proposes a deep-learning-driven inversion framework for shear modulus estimation in MRE (DIME) to improve the robustness and accuracy of inversion.
Methods:
DIME was trained on displacement-stiffness pairs generated through finite element modeling (FEM), using small image patches to capture local wave behavior and enhance robustness to global variations. Validation was performed on homogeneous and heterogeneous FEM-simulated datasets. The method was further evaluated using an anatomy-informed simulated liver dataset with known ground truth (GT) and directly compared with MMDI. Finally, DIME was tested on in vivo liver MRE data from eight healthy and seven fibrotic subjects.
Results:
In FEM simulations, DIME produced stiffness maps with low inter-pixel variability, accurate boundary delineation, and higher correlation with GT than MMDI. In anatomy-informed liver simulations, DIME reproduced stiffness patterns with high fidelity (r = 0.99, R2 = 0.98), while MMDI showed greater underestimation. In in vivo liver data, DIME preserved physiologically consistent stiffness patterns and closely matched MMDI, while MMDI demonstrated systematic over- or underestimation depending on the acquisition and filtering configuration.
Conclusions:
DIME demonstrated higher correlation with ground truth in simulations and visually similar stiffness maps in vivo, while MMDI displayed a larger bias that may be attributed to directional filtering. These results highlight the feasibility of DIME for clinical MRE applications.
Related Concept Videos
Divergence and Curl of Magnetic Field
Elastic Strain Energy for Shearing Stresses
Magnetic Resonance Imaging
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...