Related Experiment Video
Updated: Jun 12, 2026

Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
Design and experimental evaluation of a high-accuracy air temperature measurement instrument for meteorological
Keya Yuan1, Lin Li2, Yuan Chen3
1College of Robotics, Beijing Union University, Beijing 100101, China.
Abstract:
High-accuracy surface air temperature measurements (typically within 0.05-0.1 °C) are essential for atmospheric research and climate science applications. However, such measurements are affected by multiple sources of uncertainty, including radiation-induced temperature deviations and sensor time response characteristics. To address these challenges, this study develops and experimentally evaluates a high-accuracy air temperature measurement instrument designed to minimize radiation-induced errors. The principal sources of measurement deviation-direct solar radiation, diffuse and reflected components, long-wave radiation, altitude-related air density, wind speed, and solar incident angle-are systematically analyzed. A novel instrument incorporating a streamlined air-guiding structure is proposed to enhance convective ventilation and reduce radiative heating. A computational fluid dynamics (CFD) model is established to quantify radiation-induced temperature deviations under various environmental conditions. Based on the CFD-generated dataset, a multilayer perceptron-based correction model is developed to perform multi-parameter nonlinear correction of radiation-induced temperature deviations. Comparative field experiments, conducted using a 076B fan-aspirated instrument as a reference, show that the proposed instrument achieves a root mean square error of 0.019 °C and a mean absolute error of 0.015 °C under the tested conditions. Radiation-induced temperature deviations are effectively constrained within 0.05 °C, indicating that the combined structural design and correction approach can significantly improve measurement accuracy.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Distance Corrections
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...

