Comparative analysis of measurement discrepancy and reliability between direct and scanner-based methods in hand anthropometry
Related Experiment Video
Updated: Jun 13, 2026

Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Jakkapong Inprom1, Klangduen Pochana1, Supapan Chaiprapat1
1Smart Industry Research Center, Department of Industrial and Manufacturing Engineering, Faculty of Engineering, Prince of Songkla University, Hatyai Campus, Songkhla 90110, Thailand.
Abstract:
BackgroundAccurate hand anthropometry underpins ergonomics, product design, medical applications, and occupational safety. Direct caliper-based measurement (DM) is labor-intensive and operator-dependent, whereas two-dimensional flatbed scanning (SC) has been advanced as a faster alternative, with validity for small anatomical landmarks remaining uncertain.ObjectiveThe objective of this study was to quantify between-method agreement and time efficiency of two-dimensional flatbed scanning (SC) relative to direct caliper measurement (DM).MethodsIn this study, 56 hand dimensions (36 lengths, 20 breadths) were obtained from 40 Thai adults (20 males, 20 females) by DM and SC. Between-method agreement were evaluated using mean absolute error (MAE), technical error of measurement (TEM), relative TEM (%TEM), and the coefficient of reliability (R). Time efficiency was quantified from average technician time and participant handling time.ResultsPre-specified acceptability criteria (MAE ≤ 1 mm; TEM ≤ 2 cm; %TEM ≤ 1.5%; R ≥ 0.80) were satisfied by 42 of 56 dimensions (75%). Lengths and general breadths showed high agreement with the reference and strong repeatability (%TEM < 1.5%; R > 0.95), whereas small features-particularly finger-joint breadths < 25 mm-exhibited larger errors (%TEM 2.25-4.90%) and lower reliability (R < 0.80). Technician time was reduced from 30.85 to 14.10 min with SC, and participant handling was minimized (∼2.10 min).ConclusionOverall, SC can be adopted as a rapid, low-burden method for most hand dimensions, while refined protocols (e.g., increased image resolution, controlled hand pressure and posture, or equipment calibration) are indicated for sub-25-mm landmarks to ensure precision and strengthen population-specific anthropometric databases.
Related Concept Videos
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Uncertainty in Measurement: Accuracy and Precision