Related Experiment Video
Updated: Jun 13, 2026

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
A Two-Stage Deep Learning Method for Non-Invasive Sow Body Temperature Prediction Fusing Thermal Imaging and
Shengyong Xu1,2, Ziyi Qin1, Qiao Huang1
1College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.
None:
Traditional rectal temperature measurement in pigs induces stress in animals, imposes a heavy labor burden on staff, and increases the risk of cross-infection. This study proposes a non-invasive deep learning approach to predict porcine rectal temperature by combining infrared thermal images of thermal windows with environmental parameters. A multimodal dataset is constructed by synchronously collecting thermal images, environmental parameters, and actual rectal temperatures. Mask Region-based Convolutional Neural Network (Mask R-CNN), You Only Look Once version 8 small (YOLOv8s), and YOLOv11s are employed to automatically detect or segment thermal window regions, from which the maximum temperature of each region is extracted. To enhance model generalization under varying environmental conditions, a two-stage hybrid regression framework is established. In this framework, a Convolutional Neural Network (CNN) extracts spatial features from thermal images, a fully connected network (FCNN) encodes regional surface temperatures and environmental parameters, and a Transformer module captures cross-modal dependencies to generate a preliminary prediction. Subsequently, a Random Forest (RF) regressor is applied for residual correction and final output optimization. Comparative experiments on single-region, dual-region, and triple-region combinations demonstrate that the "eye + vulva" dual-region scheme yields the optimal performance, with a mean absolute error (MAE) of 0.1796 °C and a coefficient of determination (R2) of 0.8212. The prediction error of this scheme is reduced by 42.3% compared with the best-performing unimodal model. The proposed method provides a fast, accurate, and stress-free solution for porcine body temperature monitoring, thereby supporting the development of intelligent health management in livestock farming.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...