MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
Singular Value Decomposition-Based Coil Combination Improves the Accuracy and Noise-Robustness of Quantitative
Caleb Atkins1, Tianxia Wu1, Brandon Bujak1
1National Institute of Neurological Disorders and Stroke, NIH, Bethesda, MD 20892, USA.
None:
Most high-field MRI scanners conduct imaging using phased-array coils, in which the signals received by an array of coil elements are combined for downstream processing. Optimally combining these signals requires knowledge of each coil's spatial sensitivity profile, which can be acquired from a volume coil with homogeneous sensitivity across the field-of-view. However, this approach is not often used on high-field MRI scanners, especially on non-clinical systems; therefore, this work uses an algorithm based on the singular-value decomposition (SVD), called SVD-B1, to estimate coil sensitivities directly from the array data itself. Images produced by SVD-B1 are devoid of wormhole artifacts and open-ended fringe lines commonly seen in more conventional reconstructions. Quantitative Susceptibility Maps (QSMs) produced using the algorithm were compared to those produced using other combination algorithms across clinically relevant regions of in-vivo and postmortem human brains. As progressive levels of simulated noise were added to the data, SVD-B1's QSMs were up to 3% (in-vivo) and 13% (postmortem) more consistent (as measured by their Intraclass Correlation Coefficient) than those from other algorithms. Additionally, these QSMs were up to 8.5% (in-vivo) and 36% (postmortem) more accurate than other QSMs with respect to a "single-coil" reference. A parallel imaging extension of SVD-B1, called SVD-B1 GRAPPA, achieved similar results for QSMs generated from progressively more accelerated acquisition data. These results show that SVD-B1 can improve the sensitivity of high-resolution QSM to subtle changes in fine-grained tissue structures (e.g., in neurodegenerative disease) and help reduce scan times in clinical settings where shorter scans are imperative.
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...