Related Experiment Video
Updated: Jun 13, 2026

07:32
Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
Published on: February 23, 2024
3D predictability assessment of clear aligners versus fixed appliances using CBCT
Subash Chandra Nayak1, Madhu Bhaskar Bommasani2, Uday Sagar Maddula N V2
1Department of Orthodontics and Dentofacial Orthopaedics, Hi-Tech Dental College and Hospital, Bhubaneshwar, Odisha, India.
Bioinformation
|June 12, 2026
Summary
Clear aligners and fixed orthodontic appliances show comparable overall predictability in complex cases. However, clear aligners are more accurate for incisor torque and intrusion, while fixed appliances excel in rotation and extrusion.
Area of Science:
- Orthodontics
- Dental Imaging
- Biomechanical Engineering
Background:
- Limited three-dimensional (3D) comparative evidence exists for orthodontic tooth movement predictability between clear aligners and fixed appliances, especially in complex cases.
- Understanding modality-specific accuracy is crucial for optimizing treatment outcomes in orthodontics.
Purpose of the Study:
- To prospectively compare the 3D predictability of orthodontic tooth movement between clear aligners and fixed appliances in complex cases.
- To quantify accuracy across three planes of space using cone-beam computed tomography (CBCT) superimposition.
Main Methods:
- A prospective randomized study involving 60 complex orthodontic patients (30 clear aligners, 30 fixed appliances).
- CBCT scans were taken at baseline, planned, and post-treatment.
- Superimposition of CBCT scans quantified tooth movement accuracy in three planes.
Main Results:
- Clear aligners demonstrated higher accuracy in incisor torque (87.3% vs. 82.2%) and anterior intrusion (91.2% vs. 82.8%).
- Fixed appliances were superior for canine/premolar rotation (88.9% vs. 78.6%) and anterior extrusion (85.7% vs. 76.2%).
- Overall treatment predictability was comparable (clear aligners: 84.6% ± 7.8%; fixed appliances: 82.3% ± 8.9%).
Conclusions:
- Both clear aligners and fixed appliances have modality-specific strengths for different orthodontic tooth movements.
- CBCT-based evidence supports informed modality selection in complex orthodontic cases for enhanced precision.
- This study provides valuable data for clinicians planning orthodontic treatment.
Keywords:
Clear alignerscone-beam computer tomography (CBCT)fixed appliancesorthodontic predictabilitythree-dimensional analysistooth movementtreatment planning