Related Experiment Video
Updated: Jun 16, 2026

Measurements of Soil Carbon by Neutron-Gamma Analysis in Static and Scanning Modes
Published on: August 24, 2017
Accurate alpha-particle stopping power measurements in graphenic carbon foils and their application to
Konstantina Botsiou1, Sivaji Purushothaman2, Hans Geissel3,4
1GSI Helmholtzzentrum für Schwerionenforschung, Planckstraße 1, 64291, Darmstadt, Germany. k.botsiou@gsi.de.
Abstract:
A precise, non-destructive method for determining the areal density of thin graphenic carbon (GC) foils via alpha-particle energy loss is presented. Two types of GC foils - sourced from KETEK GmbH and Applied Nanotech Inc. - were investigated using a three-isotope mixed alpha source emitting particles in the 5.0-5.8 [Formula: see text] range. Both foils have similar nominal areal densities of approximately [Formula: see text], but differ slightly in chemical composition and microstructure. High-resolution alpha spectroscopy yielded energy-loss measurements with relative uncertainties below 1%. The uncertainty of the extracted areal densities and stopping powers is dominated by the determination of foil mass, area and composition metrology, rather than by the alpha-energy-loss measurement itself. Experimental stopping powers were obtained by combining the measured energy loss with independently determined foil masses and areas, and were compared with established stopping-power models. A modified Bethe formalism incorporating Barkas and Bloch corrections, together with an empirically adjusted mean excitation energy [Formula: see text], provided the most consistent description of the data across the investigated energy range. The resulting values were [Formula: see text] for the KETEK foil and [Formula: see text] for the Applied Nanotech foil. The fitted stopping-power curves indicate a systematic difference between the two GC foils, consistent with their differing compositions and microstructures. Because the stopping-power model is calibrated against the same reference foils, however, this interpretation is model-dependent and requires further validation using independently characterised samples. While the method is well suited to thin foils, angular straggling and the non-linear energy dependence of the stopping power may limit its applicability beyond the thin-target approximation. The reported stopping-power data are relevant for benchmarking Monte Carlo simulations and modelling energy deposition in carbon-based materials, with applications in accelerator technology and radiopharmaceutical research. In medical physics, stopping power is closely related to linear energy transfer, which governs the biological effectiveness of alpha-emitting isotopes in targeted therapies.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
High-Resolution Mass Spectrometry (HRMS)