Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
A New Approach to the Analysis of Dissolved Gases Using Passive Samplers, With Portable Mass Spectrometry and Gas
Antoine Picard1,2, Florent Barbecot1,2, Matéo Lacheux1,2
1Chaire UNESCO Changements Environnementaux à l'Échelle du Globe, Université du Québec à Montréal, Montréal, Canada.
Rationale:
Portable mass spectrometry systems such as miniRUEDI enable rapid and low-cost field analysis of dissolved gases with high temporal resolution. However, they remain poorly suited for discrete small-volume water samples. This study presents an approach based on passive sampling for groundwater and surface waters dissolved gases and gas tracer analyses.
Methods:
Passive samplers (≈25 mL) were deployed in near-air-saturated water for several days to equilibrate with dissolved gases. After retrieval and locking, gas samples were analysed in the laboratory using the miniRUEDI portable mass spectrometry combined with gas chromatography-electron capture detection (GC-ECD).
Results:
The combined miniRUEDI and GC-ECD approach enabled reliable and simultaneous measurements of major gases (N2 and O2), noble gases (He, Ar and Kr), and transient tracers including SF6, CFC-12 and CFC-113 from a single 25 mL gas sample. The time required for complete equilibration within the passive samplers was found to be approximately 2 days.
Conclusions:
This method extends portable mass spectrometry to discrete low-volume water samples and facilitates the use of transient anthropogenic gas tracers for determining young groundwater ages (< 70 years). Its simplicity, low cost and multi-gas capability also make it promising for tracer plume mapping and environmental monitoring applications.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...