CO2 capture by fluorinated-imidazolium based ionic liquids: a multiple minima hypersurfaces analysis.

Jennifer Cuellar1,2, Osvaldo Yáñez3, Sol M Mejía1

  • 1Línea de Investigación en Química Computacional, Grupo de Investigación GIFUJ, Departamento de Química, Facultad de Ciencias, Pontificia Universidad Javeriana, Bogotá, Colombia.

Summary

Ionic liquids (ILs) show promise for CO2 capture, with fluorine substitution enhancing CO2 affinity. While some ILs exhibit high binding capacity, the capture process is not spontaneous under simulated conditions.

Related Concept Videos

Sublimation01:03

Sublimation

Sublimation is the direct transformation of a solid to a gaseous state. For instance, at standard pressure and room temperature, solid carbon dioxide sublimes to gaseous carbon dioxide. The phase diagram depicts the conditions required for sublimation. This process occurs at the solid-gas phase boundary and is not observed above the triple point of the substance. The reverse of sublimation is called deposition, where a gaseous substance condenses directly into a solid. Sublimation and...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current passing...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.