Zhengyang Ming1,2,3,4, Arutyun Pogosyan2, Xinyu Dong2
1Physics and Biology in Medicine Graduate Program, University of California, Los Angeles, California, USA.
Background:
Existing strategies for free-breathing cine cardiac MR, including real-time imaging, struggle with complex arrhythmias such as atrial fibrillation (AF). Dynamic regularized adaptive clustering optimization (DRACO) has been proposed to generate high-quality and quantifiable breath-held cine images for patients in AF.
Purpose:
To tailor DRACO for free-breathing and evaluate its potential to simultaneously handle cardiac and respiratory motion.
Study Type:
Prospective.
Subjects:
10 sinus rhythm (10 males), 20 AF (18 males).
Field Strength/Sequence:
3.0 T, balanced steady-state free precession (bSSFP) with sorted golden-step, ECG-gated segmented cine, and real-time.
Assessment:
Patients were imaged using the golden-step sequence under breath-held and free-breathing conditions, and the reference bSSFP cine sequence. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, and image quality (4-point Likert scale) were assessed.
Statistical Tests:
Paired t-test, Friedman test, regression analysis, Fleiss' Kappa. Significance level p < 0.05.
Results:
The SNR and CNR values of DRACO images showed no significant differences between breath-held and free-breathing conditions in both sinus rhythm (SNR p = 0.53; CNR p = 0.87) and in AF (SNR p = 0.56; CNR p = 0.55). Image sharpness was not significantly different between breath-held and free-breathing in both sinus rhythm (p = 0.24) and AF (p = 0.79). In AF patients, breath-held DRACO and free-breathing DRACO had significantly higher image quality scores than real-time cine. In sinus rhythm patients, there was no significant difference (p = 0.13) between breath-held or free-breathing DRACO and segmented cine. Despite significant within-patient ejection fraction (EF) differences between breath-held versus free-breathing in 80% of sinus rhythm and 70% of AF patients, the average EF between breath-held versus free-breathing DRACO showed high correlation (sinus rhythm R 2 = 0.71; AF R 2 = 0.71), demonstrating DRACO's robustness to motion variation.
Data Conclusion:
DRACO is robust to respiratory motion and AF-related irregular cardiac motion. It enables high-quality cine image generation in both regular and irregular cardiac motion, with or without breath holding.
Technical Efficacy:
Stage 2.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System V: CT
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...