Related Experiment Video
Updated: Jun 17, 2026

07:57
Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
Dimensional accuracy of dental impression materials evaluated using a standardized CAD based method across materials
Christoph Wassermann1, Nico Rosenberger1, Marcel Gerhardt2
1Department of Prosthodontics, University of Wuerzburg, Pleicherwall 2, 97070, Wuerzburg, Germany.
Scientific Reports
|June 15, 2026
Summary
Vinyl polysiloxane (VPS) and polyether (PE) dental impression materials demonstrated superior dimensional accuracy compared to vinyl siloxanether (VSE). Material choice significantly impacts accuracy, with all tested materials meeting international standards.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Prosthodontics
Background:
- Accurate dental impressions are crucial for fabricating well-fitting restorations.
- Dimensional stability of elastomeric impression materials is a key factor in clinical success.
- Existing standards, such as DIN EN ISO 4823, define acceptable dimensional changes.
Purpose of the Study:
- To establish a CAD-based workflow for evaluating the dimensional accuracy of dental impression materials.
- To compare the dimensional stability of vinyl polysiloxane (VPS), polyether (PE), and vinyl siloxanether (VSE) materials.
- To assess the influence of impression techniques (guided vs. freehand) and tray types (stock vs. custom) on accuracy.
Main Methods:
- An in vitro study utilizing a rigid metal reference arch with four spheres.
- Ninety double-mix impressions were made using VPS, PE, and VSE materials with stock and custom trays in guided and freehand techniques.
- Impressions were cast in Type IV dental stone, digitized, and analyzed by comparing linear inter-sphere distances to the reference model.
Main Results:
- VPS and PE materials exhibited significantly lower global deviations than VSE materials.
- No significant difference in accuracy was found between VPS and PE materials.
- Impression technique (guided vs. freehand) and tray type (stock vs. custom) showed no significant impact on dimensional accuracy under the tested conditions.
- All tested materials demonstrated deviations below the 1.5% linear-change threshold specified by DIN EN ISO 4823.
Conclusions:
- Material selection is the primary determinant of global dimensional accuracy in dental impressions.
- VPS and PE are superior to VSE in terms of dimensional stability for conventional dental impressions.
- The established CAD-based workflow provides a reliable method for evaluating impression material accuracy.