Related Experiment Video
Updated: Jun 17, 2026

Single-Molecule Diffusion and Assembly on Polymer-Crowded Lipid Membranes
Published on: July 19, 2022
The non-linear effects of the number of stochastic single-molecule adsorption events on ensemble elution profiles
Ricardo Monge Neria1, Rachel A Saylor2, Lydia Kisley1,3
1Department of Physics, Case Western Reserve University, Cleveland, Ohio 44106, USA. lydia.kisley@case.edu.
Abstract:
The stochastic model of chromatography mathematically represents the molecular mass transfer that occurs during a separation. Single-molecule microscopy allows for direct visualization of molecular analytes adsorbing within column materials. Experimental single-molecule data and the stochastic model can predict elution profiles using the adjustable variable r̄m, the average number of adsorptions per molecule. Previously, only a single r̄m value was used to match either peak location or shape, while the effects of adjusting np, the number of modeling points, have not been studied. Here, we systematically explore a wide range of these two variables in the stochastic model to determine if it is possible to optimize agreement between modeled single-molecule and high-performance liquid chromatography (HPLC) chromatograms. A metric to quantify chromatogram agreement is introduced by taking the weighted difference in the elution time and shape of the chromatograms. We determine the non-linear effects of r̄m and np on peak height, width, and asymmetry and link the observations to the molecular behavior. Applying our approach to experiments with variable flow rate shows that increased sampling of rare, long time adsorption events affects agreement between simulated and HPLC elution profiles. Finally, we make quantitative recommendations that the single-molecule experiments should sample available binding sites following an exponential association model and that np must be > 1.5 × r̄m to achieve accurate results. Overall, we verify that the current form of the stochastic model based solely on mass transfer is unable to simultaneously match both peak location and shape and make recommendations for future improvements to the model by separation scientists.
Related Concept Videos
Analyte Adsorption and Distribution
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Adsorption Isotherms I
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...

