Related Experiment Video
Updated: Jun 17, 2026

MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Hybrid Cardiac 68Ga-FAPI-4 PET/MRI in Dilated Cardiomyopathy: A Feasibility and Pilot Study.
Yaqiong Zhou1,2,3, Hua Lin4, Chuan Huang1,2
1Department of Cardiology, Department of Medicine, West China Hospital, Sichuan University, Guoxue Xiang, No. 37, Chengdu 610041, Sichuan, China.
A new cardiac gallium 68-labeled fibroblast activation protein inhibitor (FAPI)-4 PET/MRI protocol efficiently assesses nonischemic dilated cardiomyopathy (DCM). This hybrid imaging approach successfully identifies myocardial remodeling and disease, demonstrating excellent diagnostic performance.
Area of Science:
- Cardiovascular Imaging
- Molecular Imaging
- Nuclear Medicine
Background:
- Cardiac gallium 68-labeled fibroblast activation protein inhibitor (FAPI)-4 (68Ga-FAPI-4) PET/MRI offers simultaneous assessment of cardiac tissue characteristics, function, and molecular remodeling in myocardial diseases.
- An integrated workflow for nonischemic dilated cardiomyopathy (DCM) using this modality is currently lacking.
Purpose of the Study:
- To evaluate the feasibility and diagnostic performance of a time-efficient cardiac 68Ga-FAPI-4 PET/MRI protocol in participants with DCM.
Main Methods:
- A prospective study enrolled participants with DCM and healthy controls for hybrid 68Ga-FAPI-4 PET/MRI.
- Oncology patients without cardiovascular disease undergoing 68Ga-FAPI-4 PET/CT served as an additional control group.
- Hybrid PET/MRI included cine imaging, T1/T2 mapping, and late gadolinium enhancement (LGE); myocardial FAPI uptake was quantified and correlated with MRI and clinical markers.
Main Results:
- The hybrid protocol was feasible, with mean cardiac MRI acquisition and scanner room times of 32.0 ± 6.0 and 37.6 ± 6.6 minutes, respectively.
- Sixty-eight percent of DCM participants showed elevated myocardial FAPI uptake, exceeding LGE extent in 73% of positive cases.
- FAPI uptake was absent in healthy and oncology controls; excellent diagnostic performance for DCM was observed (AUCs ranging from 0.83 to 0.92).
Conclusions:
- Hybrid cardiac 68Ga-FAPI-4 PET/MRI is a feasible and effective method for simultaneous molecular and structural imaging in nonischemic DCM.
- The protocol demonstrates high diagnostic accuracy for identifying DCM, correlating well with cardiac structure and function parameters.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
