Concordance of HbA1c, creatinine, LDL cholesterol, HDL cholesterol, and total cholesterol between venous and

Linda Hoffmeister1, Christopher Schuchardt1, Angelika Hafke2

  • 1Department of General Practice, University Medical Center, Göttingen, Germany.

Insights

Self-collected capillary blood tests are reliable for remote monitoring of HbA1c, creatinine, and lipids. Mailed capillary samples show high concordance with venous samples, improving access to routine health assessments.

Area of Science:

  • Clinical Chemistry
  • Point-of-Care Testing
  • Health Services Research

Background:

  • Routine monitoring of HbA1c, creatinine, and lipids is crucial for managing chronic conditions like diabetes.
  • Traditional venous blood sampling requires in-person visits, potentially limiting access for some patient populations.
  • Evidence on the accuracy of self-collected capillary blood samples sent via mail, under real-world transport conditions, is limited.

Purpose of the Study:

  • To evaluate the concordance of key biochemical parameters (HbA1c, creatinine, lipids) between self-collected capillary blood samples sent by mail and concurrently collected venous blood samples.
  • To compare mailed capillary samples (CMS) and mailed venous samples (VMS) against courier-transported venous samples (VCS) to assess the impact of different transport methods.

Main Methods:

  • A cross-sectional study involving 105 participants who provided self-collected capillary blood samples using the Tasso+ device.
  • Participants also provided two venous blood samples: one mailed with the capillary sample (VMS) and one sent via courier (VCS).
  • HbA1c, creatinine, LDL, HDL, and total cholesterol levels were measured in all sample types.

Main Results:

  • High concordance was observed for HbA1c (CCC=0.999) and creatinine (CCC=0.972) between mailed capillary samples (CMS) and courier-transported venous samples (VCS).
  • Mailed venous samples (VMS) also showed high agreement with VCS for HbA1c (CCC=0.998) and creatinine (CCC=0.990).
  • Lipid parameters demonstrated good concordance (CCC >0.95) across CMS and VMS compared to VCS, with low relative bias.

Conclusions:

  • Self-collected capillary blood samples transported by standard mail demonstrate comparable results to venous blood samples for HbA1c, creatinine, and lipid profiling.
  • Capillary self-sampling offers a reliable and accessible method for remote patient monitoring.
  • This approach holds significant potential for improving diabetes management and screening accessibility.
Abstract

Related Concept Videos