Bone remodelling around internal fracture fixations used for treating femoral neck fractures: A finite element analysis
Related Experiment Video
Updated: Jun 18, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Biswajit Mahapatra1, Swapnil Mahadev Dhobale1, Kishore Pradeep1
1Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah, West Bengal, India.
Abstract:
Femoral neck fractures necessitate effective fracture fixation techniques to ensure optimal outcomes. The study evaluates the bone remodelling around Dynamic Hip Screw with anti-rotational screw (DHS + AR) and Femoral Neck System (FNS) used for treating femoral neck fractures of Pauwels types I, II and III. Femur models were developed using CT imaging data. Fractures were modelled assuming smooth fracture surfaces. Isotropic heterogeneous CT-grey value-based bone material properties were employed in the bone model, and Ti-alloy was incorporated as implant material. Bone remodelling algorithm based on strain energy density was employed to predict the implants' effects under two loading conditions: normal walking and stair climbing. The density change (Δρ) was iteratively updated until convergence occurred (Δρ < 0.005 g/cm3 between two consecutive iterations). The investigation compared post-operative (PO) conditions with equilibrium (AE) states. Results revealed that strain shielding was approximately 27% lower in FNS-implanted models than DHS + AR models, indicating better biomechanical performance under adopted modelling assumptions. From PO to AE, axial deformation and rotational stability of the femoral head were reduced more in FNS models, with reductions of up to 13.57% and 83%, respectively. Micromotion was (below 100 μm) in all models except for FNS in Pauwels III fractures under PO conditions. However, it was reduced below 100 μm at AE. Lower bone loss was observed in FNS-implanted models while DHS + AR implanted models exhibited higher resorption. These findings suggest that FNS implants are predicted to provide better stability and favourable bone remodelling outcomes compared to DHS + AR screws.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bone Remodeling and Repair
Bone Remodeling