Improved pancreatic imaging with photon-counting CT: a retrospective comparison with conventional CT
Erik Gudmann Steuble Brandt1, Felix Christoph Müller1, Yousef Jw Nielsen1
1Department of Radiology, Copenhagen University Hospital, Herlev and Gentofte, Denmark.
None:
BackgroundImaging is crucial for the detection of pancreatic diseases. Photon-counting computed tomography (PCCT) is a recent improvement in CT detector technology that may improve pancreatic imaging quality.PurposeTo compare the image quality in pancreatic imaging with PCCT versus conventional CT (EIDCT) both subjectively and quantitatively.Material and MethodsWe retrospectively identified 35 patients scanned with both EIDCT and PCCT in multiple contrast phases. Image quality over 11 peripancreatic areas was rated on a 5-point Likert scale. One reader made quantitative measurements of density and noise. Data analysis was performed using R Studio. Continuous data were compared using a paired t-test and ordinal data with a Wilcoxon signed-rank test.ResultsImage quality was rated significantly higher on PCCT for the pancreatic parenchyma in the late arterial phase (3.87 vs. 2.77; P <0.01), the pancreatic parenchyma in the portal venous phase (3.31 vs. 2.53; P <0.01), pancreatic ducts (2.88 vs. 2.62; P <0.01), superior mesenteric artery (4.10 vs. 2.74; P <0.01), coeliac axis (4.04 vs. 2.70; P <0.01), and portal vein (3.29 vs. 2.52; P <0.01). Noise levels were significantly lower with PCCT with a mean reduction of 5.8 HU across all areas. Dose-length-product was significantly reduced in both the late arterial phase (31.8%; P <0.01) and the portal venous phase (21.5%; P <0.01).ConclusionImage quality was subjectively and quantitatively significantly improved for all evaluated pancreatic and peripancreatic structures with PCCT compared to EIDCT. In addition, radiation dose was significantly reduced.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET