Measuring the Behavioral Effects of Intraocular Scatter
Published on: February 18, 2021
Evaluating measurement accuracy of ear-canal reflectance using a conical horn
Joshua J Hajicek1, Sara E Harris1, Kren Monrad Nørgaard2,3
1Center for Hearing Research, Boys Town National Research Hospital, Omaha, Nebraska 68131, USA.
Abstract:
Acoustic reflectance is fundamental to the set of ear-canal measures collectively known as wideband acoustic immittance (WAI). The potential of WAI to inform diagnostic audiology, and its broader clinical adoption, remain active areas of study. Individual variability, challenges in diagnostic interpretation, and the lack of adopted standards for quantifying measurement accuracy are barriers to wider clinical use. This study builds upon a previously proposed theoretical framework for validating reflectance measurements. Specifically, we demonstrate a method for checking (1) the accuracy of WAI device measurements and (2) consistency across repeated measurements. We describe an updated acoustic horn design and use it as a physical reference waveguide with a known analytic solution to verify measurement accuracy. Quantitative comparisons of reflectance measurements to the horn's analytic solution were performed using a total of six three-dimensional (3D)-printed horns. These comparisons yielded Pearson correlations of 0.98-0.99 and maximum absolute deviations in reflectance magnitudes below 0.02. The proposed horn is inexpensive to reproduce and could function as part of a reference standard for validating acoustic reflectance, help explain sources of variability, and contribute to wider clinical acceptance of WAI by increasing user confidence in measurement consistency and accuracy.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...