Added value of photon-counting CT for triple rule-out imaging: A propensity-matched comparison with
Sardi Hyska1, Milán Vecsey-Nagy2, Tilman Emrich3
1Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany.
Purpose:
To compare the technical performance of photon-counting detector (PCD)-CT and energy-integrating detector (EID)-CT in triple rule-out (TRO) imaging.
Methods:
In this IRB-approved single-center study, consecutive TRO-CT patients underwent dual-source EID-CT or PCD-CT with 75 or 98.5 mL iopromide. Propensity score matching generated four groups: EID-75, EID-98.5, PCD-75 and PCD-98.5. Axial polychromatic images were reconstructed at 1.0 mm for whole-thorax and 0.6 mm for coronary assessment using a vascular kernel (Bv36). Volume CT dose index (CTDIvol), contrast-to-noise ratio (CNR), and diagnostic confidence (Likert 4, excellent) were compared across vascular territories. Diagnostic performance for coronary stenosis was assessed in patients undergoing invasive coronary angiography.
Results:
A total of 96 subjects (mean age 62.0 ± 13.1 years; 62.5% female, n = 24 per group) were included. TRO-CT ruled out aortic, coronary and pulmonary pathology in 69/96 (71.9%) patients. PCD-CT showed 32.3% lower CTDIvol than EID-CT (29.3 [23.5-41.4] vs 43.3 [36.6-51.0] mGy; p < 0.001). PCD-98.5 yielded the highest CNR (aorta, 32.2 [25.5-44.1]; coronaries, 24.5 [19.5-31.3]; and pulmonary arteries, 36.8 [28.0-45.3]; all p < 0.001). Pulmonary CNR with PCD-75 was comparable to EID-98.5 despite lower contrast volume (22.4 [19.1-28.8] vs 24.2 [20.3-29.6]; p = 0.437). Segmental pulmonary diagnostic confidence increased from fair (2 [1-3]) with EID-98.5 to excellent (4 [3-4]) with PCD-98.5 (p < 0.001). TRO-CT showed coronary segment-based sensitivity of 94.4% (17/18) and specificity of 93.2% (218/234), with no AUC difference between EID-CT and PCD-CT (0.961 vs 0.936; p = 0.361).
Conclusion:
PCD-CT enabled robust TRO imaging with lower radiation dose, higher multi-territory CNR, and greater segmental pulmonary diagnostic confidence, addressing key limitations of conventional TRO protocols.
More Related Videos
07:13Multimodal Cross-Device and Marker-Free Co-Registration of Preclinical Imaging Modalities
Published on: October 27, 2023
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...