Related Experiment Video
Updated: Jun 23, 2026

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
CineScribe: LLM-based detection and mitigation of ambiguity in cine cardiac magnetic resonance reports
Guillermo Villanueva Benito1, Martin L Descalzo2, Sandra Pujadas3
1Barcelona Institute for Global Health (ISGlobal), C/ del Dr. Aiguader 88, Barcelona, 08003, Spain; Universitat Pompeu Fabra (UPF), Barcelona, 08003, Spain.
Abstract:
Cine Cardiac Magnetic Resonance (cineCMR) is widely regarded as a reference standard for evaluating left-ventricular wall motion, yet interpretation remains variable and free-text reports frequently contain imprecise language that can lead to miscommunication. In this study, we present CineScribe, a novel lightweight large language model (LLM) trained on expert-annotated cineCMR reports to convert free-text clinical reports into structured regional wall-motion abnormality (RWMA) representations and support standardized report generation from validated diagnostic findings. CineScribe achieves high performance on the report-structuring task with a macro-F1 of 0.92 (95% CI, 0.89-0.94), enabling automated extraction of RWMAs from routine clinical documentation. Beyond structuration, we introduce a Report-Level Confidence (RLC) score, derived from token-level conditional probabilities of the model, to quantify uncertainty during structured information extraction. Using an enriched multi-expert annotated dataset, we show that reduced model confidence is strongly associated with report ambiguity, which in turn corresponds to diagnostically complex cineCMR cases characterized by increased inter-observer variability during expert video review. CineScribe detected ambiguous reports with good discrimination with a ROC-AUC of 0.76 (95% CI, 0.68-0.85). Human evaluation using the QUEST framework demonstrated that reports generated from expert-validated findings were clinically appropriate, with 78% (95% CI, 74%-83%) rated as both correct and complete. Together, these results show that model confidence during clinical information extraction can serve as a practical indicator of ambiguity in medical reporting, enabling targeted expert review of diagnostically complex cases and supporting more consistent and efficient cineCMR documentation.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
