A randomized crossover clinical trial of the Deseyne contact lens for presbyopia with extended depth of focus
Related Experiment Video
Updated: Jun 23, 2026

Correction of Presbyopia by Monocular Bi-Aspheric Ablation Profile
Published on: September 20, 2024
Mark A Bullimore1, Charles B Slonim2, Stephen M Montaquila3
1College of Optometry, University of Houston, Houston, Texas, USA.
Purpose:
To evaluate the visual performance of a new daily wear presbyopia contact lens (Deseyne contact lens for presbyopia with extended depth of focus).
Methods:
This was a randomized, crossover, and nondispensing clinical trial. Seventy-eight presbyopic (45-70 years, mean = 53.9 years) habitual soft contact lens wearers were recruited with spherical refractive errors between -6.00 and +4.00 D and less than 1.25 D astigmatism. Subjects were fitted bilaterally with the Deseyne lens and a control monofocal contact lens and randomized as to which of the study lenses would be tested first. Effectiveness measures included monocular lens-induced depth of focus testing-the primary effectiveness measure-and monocular distance, intermediate, and near visual acuity. Contrast sensitivity was also measured at mesopic luminance with and without glare.
Results:
Mean monocular distance visual acuity was 0.00 ± 0.07 and -0.07 ± 0.07 logMAR with the Deseyne and control lens, respectively. The corresponding mean monocular intermediate visual acuity was +0.02 ± 0.11 and +0.16 ± 0.14 logMAR and monocular near visual acuity was +0.20 ± 0.11 and +0.35 ± 0.17 logMAR. Mean depth of focus was 2.22 ± 0.78 D with the Deseyne lens and 1.44 ± 0.67 D with the monofocal control. The mean extended depth of focus (95% CI) was thus 0.78 (0.63, 0.93) D. Contrast sensitivity was significantly lower with the Deseyne lens at 3, 6, and 12 cycles per degree with and without glare.
Conclusions:
The Deseyne contact lens for presbyopia with extended depth of focus extends the depth of focus of the eye and thus improves intermediate and near visual acuity.
Related Concept Videos