Related Experiment Video
Updated: Jun 23, 2026

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Detection and interference analysis of lead in acid-containing fruits using gel/graphite paper electrode based on
Yilu Huang1, Huili Luo1,2, Jia Zhao1,2
1College of Environment and Ecology, Hunan Agricultural University, Changsha, Hunan 410128 China.
Abstract:
Electrochemical detection is an applicable rapid detection technology, but it is always limited by sample treatment and matrix interference. In this study, two gel/graphite paper electrodes were obtained by drop coating of sodium alginate gel and chitosan gel onto 0.1 mm graphite paper. Comparations of anti-interference performance and stability indicated that sodium alginate gel/graphite paper electrode (GGPBE) was the preferred term for establishing a rapid determination method for Pb in fruits. Based on the contents of organic acids and main metal ions in fruits, analysis and control of matrix interference were conducted. Organic acids, such as ascorbic acid, citric acid and quinic acid, caused greater interferences than metal ions. Mg(II) and Fe(III) were the notable factors of co-interference with organic acids. Matrix interference could be controlled in 3.92% by chemical oxidation using H2O2 combined with HNO3 ultrasonic extraction. The established linear range of Pb(II) was 0.1 ∽ 21.0 µg/L and LOD was 0.0274 µg/L under square wave anodic stripping voltammetry method. In the detection of 9 fruits, the contents of Pb were below 0.1 mg/kg. This work developed an easily prepared gel/graphite paper electrode and provided a rapid sample treating-detection method of lead in fruits.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s13197-025-06288-x.
Related Concept Videos
Electrodeposition
Electrodeposition can...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Extraction: Advanced Methods
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Capillary Electrophoresis: Instrumentation